Mold Steel Surface Coating — How Do TiN, CrN and DLC Coatings Extend Mold Life, Reduce Friction and Improve Part Release?
Last updated: 2026-09-03 · Reading time: about 6 min
A surface coating is a thin (2–5 μm) hard layer — TiN, CrN or DLC — deposited on mold steel by PVD or CVD. Match the coating to the resin: it runs 1,500–4,000 HV against the steel’s 700–900 HV, cuts friction 30–70% and extends mold life 2–10×.
See also related article.
Key facts
<>
>
Parting line — The line where the two mold halves (A-side and B-side) meet. Parting line location affects: gate placement, ejector pin marks, witness lines, and cosmetic appearance. A well-designed parting line minimizes visible witness marks. See also related guide.
What are the coating types — and how do you choose the right one?
Five coatings cover most mold work. Selection follows the resin, the mold temperature and the defect you are solving.
| Coating | Hardness (HV) | Friction | Max temp | Best for |
|---|---|---|---|---|
| TiN (titanium nitride) | 2,000–2,500 | 0.4–0.6 | 600 °C | General purpose; abrasive GF-filled resins |
| TiAlN (titanium aluminum nitride) | 3,000–3,500 | 0.4–0.6 | 800 °C | High-temperature resins (PPS, PEEK, PEI) |
| CrN (chromium nitride) | 1,800–2,200 | 0.3–0.5 | 700 °C | Corrosive resins (PVC, flame-retardant) |
| DLC (diamond-like carbon) | 3,000–4,000 | 0.05–0.15 | 200 °C | Stick-prone resins (TPE, TPU); optical parts |
| Ni (electroless nickel) | 500–700 | 0.3–0.5 | 400 °C | Corrosion protection; mirror finish |
TiN is the workhorse — the gold-colored layer on molds running glass-filled PP or PA. TiAlN takes the high-temperature resins that would oxidize TiN above 600 °C. CrN is chemically inert, so it resists the acid attack from PVC and brominated flame-retardant decomposition. DLC has the lowest friction coefficient of the group, so a TPE or TPU part releases cleanly and an optical face comes off without flow marks.
What is the coating process — and does it change the mold dimensions?
Four steps, and one number that decides whether the coating holds: the substrate hardness.
- Polish and clean first. The coating replicates the surface underneath, so the components are polished to their final finish, then ultrasonically cleaned and solvent-degreased. Any oil, grease or polishing compound left behind is trapped under the layer and turns into a pinhole, a blister or a delamination.
- Deposit by PVD, 3–6 hours at 300–500 °C. Titanium, chromium or carbon is vaporized by an arc or sputtering source in a vacuum and builds up as a uniform 2–5 μm layer, even in deep holes and complex geometry. The temperature stays below the tempering point of most mold steels, so hardness is unaffected.
- Inspect and test. Coated parts are checked for pinholes and delamination, measured for thickness by eddy current or X-ray fluorescence, tested for adhesion by a Rockwell C indentation at 150 kgf (cracking or peeling around the indent means poor adhesion), and measured for hardness by Vickers microhardness.
- Re-coat when it wears. The layer eventually wears off, and the components can be stripped and re-coated. Re-coating costs 50–70% of the original because of the stripping, and a component tolerates 3–5 cycles before the steel dimensions shift — each strip removes 1–2 μm of steel.
A coating preserves a surface; it does not create one. PVD adds only 2–5 μm that copies whatever finish is underneath, so a scratch still shows through and a soft substrate still fails. Harden the steel to at least 48 HRC and polish it to its final state before coating — below that hardness the steel deforms under injection pressure and the hard, brittle layer cracks instead of flexing with it.
“We treat the coating as a wear budget, not a cosmetic add-on. In the DFM we match the layer to the resin — TiN for glass-filled, CrN for corrosive, DLC for TPE release — and we specify hardened, polished inserts so the coating has something to hold onto. The payoff shows up as documented shot count and fewer re-polish stops, not a shinier tool.”
— Project Engineer, aCatMould
Frequently asked questions
>
What does a PVD coating cost — and when does it pay back?
Coating runs $5–15 per square inch, and DLC $15–30 because the process is slower.
A typical cavity of 100–300 square inches works out to $500–4,500 per cavity.
It pays back for high-volume molds above 500,000 shots a year (life up 2–10×), abrasive resins (wear rate down 5–10×) and stick-prone resins (ejection force down 30–70%, no release spray at $0.01–0.03 a part). Payback lands in 50,000–200,000 shots.
Do you coat the whole mold — or only specific components?
Only the components that touch the melt and wear: cavity inserts, core pins, slides and ejector pins. Base plates are left uncoated because they never contact the melt.
Parts are removed, coated in a vacuum chamber — most chambers take pieces up to 400 × 400 × 400 mm — and reassembled. The 2–5 μm layer is negligible against a 0.01–0.05 mm fit tolerance, so the fit does not change.
What are the coating limits — and when should you skip it?
A coating does not raise steel hardness (it needs a substrate at 48 HRC or above), does not fill scratches (polish first), and has a temperature ceiling — TiN oxidizes above 600 °C, DLC above 200 °C.
It also adds $500–4,500 per cavity and 1–2 weeks of turnaround. Below 100,000 shots the mold will not wear out before production ends, so the coating is not worth it.
Key takeaways
- Match the coating to the resin — TiN general and abrasive, TiAlN high-temperature, CrN corrosive, DLC stick-prone and optical, electroless nickel for corrosion plus a mirror finish.
- PVD runs at 300–500 °C and adds 2–5 μm, so dimensions hold; hardness reaches 1,500–4,000 HV and mold life goes up 2–10×.
- Harden the steel to 48 HRC and polish before coating; the $500–4,500 per cavity is justified above ~500,000 shots or for abrasive, stick-prone and corrosive resins.
A coating is a targeted fix, not a substitute for the right steel or a sound design. Match it to the resin, harden and polish the substrate first, and it buys 2–10× the shot life with lower ejection force and no release spray. If a mold is wearing, sticking or corroding, a DFM review picks the coating before the tool is cut — or before it goes back for re-coating.
Sources
Plastics Technology — mold surface coatings, wear and maintenance practice
MoldMaking Technology — PVD/CVD coatings and surface engineering for tooling
Plastics Industry Association — plastics processing and tooling resources
ASTM International — hardness and coating adhesion test methods (Vickers, Rockwell)
Society of Plastics Engineers — molding materials and process engineering
Sources: Plastics Technology · Plastics Technology Online · Society of Plastics Engineers (SPE) · ThomasNet